Digital Battery Test System
RACTS-20V
10mA-1A / 1A-5A /5A-10A / 10A-20A
Application Fields
RACTS-20V is mainly used for cycle life and quality testing of 3C digital intelligent batteries such as mobile phone batteries, digital camera batteries, and laptop batteries. It supports integrated charge/discharge data monitoring, enabling real-time, high-precision sampling, storage, analysis, and early warning of various battery parameters—providing reliable data references for R&D and production.
Testing Functions
 | Cycle life test |  | Temperature Characteristic Test |  | Charge/Discharge Test |  | Voltage Test |
 | Charge retention test |  | Static/Dynamic SOC Test |  | Overcharge/ Overdischarge Test |  | DCIR test |
Advantageous Features
Multi-range auto switching with 0.02% F.S. accuracy
Supports different current ranges: 10mA–1A/1A–5A/5A–10A/10A–20A; Automatically and seamlessly switches between ranges during testing.
| Support multi-channel parallel connection
Through the software arbitrarily set the channel independent, parallel mode of operation, the combination of changes into n different current range of the test system, very convenient, support across the box multi-channel parallel to improve the current range.
|
High precision sampling
Stable and accurate current and voltage sampling, using high-resolution ADC units with excellent long-term stability. |
Pulse condition
Supports current/power condition simulation with a minimum time interval of 50ms. Allows one-click import of working condition data to closely simulate real battery behavior.
| CCCV Charging
Constant current–constant voltage charging with seamless transition. No voltage/current impact, preventing the battery lugs from being de-powdered or the voltage overshoot caused by the interruption of the BMS switch.
| Multiple configurations available
RACTS-20V is offered in standard, tray, and drawer versions to meet different application needs.
|
Product Parameter |
VOLtage
| Scope | 2V~20V |
Accuracy | ± 0.02% F.S |
Resolution | 0.1mV |
Current | Scope | 4 Ranges :10mA-1A / 1A-5A /5A-10A / 10A-20A |
Accuracy | ± 0.02% F.S |
Resolution | 0.1mA |
Current Response Time | 5ms(10%~90% F.S) |
Current switching time | 10ms(-90%~90% F.S) |
Communication | LAN |
Third party / auxiliary module linkage | Support linkage with temperature chamber, MTV/MTS, pressure sensor, etc. |
Equipment Size (mm) | 770*722*1800 |
Note:For specific models and parameters, please refer to the corresponding technical specifications