High Voltage & High Current Battery Test System
HRCDS-750V/1000V/1500V/2000V
200A/300A/400A/500A/600A/1000A…4000A
Application
RePower high voltage high current battery test system adopts advanced instrumentation technology and power electronics technology to develop energy feedback type testing equipment, which is suitable for new energy vehicles, energy storage, battery packs and other lithium or lead-acid battery pack testing and quality control.
Test Functionality
 | Conditional Pulse Test |  | Charge/Discharge Test |  | Charge Retention Capability |  | Temperature
Characteristics Test |
 | Peak-Shifting Test |  | Dynamic and Static SOC Test |  | Cycle Life Test |  | DCIR Test |
Advantages and Features
Modular Design for Flexible Combination
Comprising: Transformer Cabinet, AC/DC Power Cabinet, DC/DC Power Cabinet, Host Computer System.Customizable, High Utilization, Easy Maintenance. | Cross-Cabinet Parallel Connection
Scale current, double capacity, maintain precision, reduce costs. |
Standard Sine Wave Energy Feedback · 96% Efficiency
Bidirectional energy-saving for charging/discharging. Reduce electricity & cooling costs. |
24-hour Offline Operation
The host computer samples high-performance multi-core CPUs,and the equipment can run offline for 24 hours after the communication interruption of the host computer, and then automatically resume after the communication is restored, so that the test will not be interrupted.
| High-Speed Working Condition Simulation
Simulate arbitrary current/power waveforms of batteries during actual driving such as vehicle startup, climbing, braking. Provide reliable and comprehensive data to help customers shorten battery development/verification cycles.
| Three-Level Design
Utilizes three-level technology for wide voltage output range, low ripple current, robust grid adaptability, reduced losses, and higher efficiency. |
Product Parameters |
Voltage | Scope | 750V~1500V…2000V |
Accuracy | ± 0.02% F.S Divided into ≤10 gears |
Resolution | 1mV |
Current | Scope | 200A/300A/400A/500A/600A/1000A…4000A |
Accuracy | ± 0.02% F.S Divided into ≤10 gears |
Resolution | 1mA |
Current response time | 3ms(10%~90% F.S) |
Current switching time | 5ms(-90%~90% F.S) |
Minimum operating interval | 10ms |
Communication | LAN |
Third-party/auxiliary module linkage | Support linkage with temperature box, MTV/MTS, pressure sensor, etc. |
Equipment size (W*D*H mm) | According to actual configuration |
Note: For specific models and parameters, please refer to the corresponding technical specifications.